Performance Evaluation of a Module Configured Active Silencer for Robust Active Noise Control of Low Frequency Noise in Ducts
Ansvarlig organisasjon
2008 (engelsk)Rapport (Annet vitenskapelig)Alternativ tittel
Prestanda Evaluering av ett Modul Konfigurerat Aktivt Bullerundertryckningssystem för robust aktiv bullerundertryckning av lågfrekvent ventilationsbuller (svensk)
Abstract [en]

Low noise level is an essential feature when installing ventilation systems today. Since the passive silencers traditionally used to attenuate ventilation noise tend to become bulky, impractical, and expensive when designed for low frequency attenuation, other solutions for the reduction of the low frequency duct noise often present in ducts are of interest. Active noise control (ANC) is a well known method for attenuating low frequency noise and much research has been performed to successfully apply ANC to duct noise. To insure reliable operation and desirable levels of attenuation when applying ANC to duct noise, it is of highest importance to be able to suppress the contamination of the microphone signals due to the turbulent pressure fluctuations arising as the microphones are exposed to the airflow in the duct. The work presented in this report is concerned with analysis of the influence of the turbulence induced noise on the adaptive algorithm in the ANC system, and design of microphone installations which produce sufficient turbulence suppression while also meeting industrial requirements. These requirements are, for example, that the installations should be based on standard ventilation parts, and that they should be easily installed and maintained. Furthermore, results concerning the performance of an ANC system with different microphone installations are presented. Some of the results were obtained at an acoustic laboratory according to an ISO standard. The attenuation of duct noise achieved with ANC was approximately 15-25 dB between 50-315 Hz, even for airflow speeds up to 20 m/s.

sted, utgiver, år, opplag, sider
2008.
Serie
Blekinge Institute of Technology Research report, ISSN 1103-1581 ; 6
Emneord [en]
Signal Processing, Adaptive filters, Active Noise Control, Ventilation noise, Measurement noise, Turbulence
HSV kategori
Identifikatorer
URN: urn:nbn:se:bth-00421Lokal ID: oai:bth.se:forskinfo1CF5A0E7619AB153C12574F2003EA923OAI: oai:DiVA.org:bth-00421DiVA, id: diva2:836098
Tilgjengelig fra: 2012-09-18 Laget: 2008-10-30 Sist oppdatert: 2015-06-30bibliografisk kontrollert

Open Access i DiVA

fulltekst(7756 kB)130 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 7756 kBChecksum SHA-512
45446b03874b810d08a53688a4adeb74848fdc5a5a03f7b269be6cd3510432342acd900a7f10b1b8dd859b87f40c03de2bb21904ec2cca09202b24ebb55f5a62
Type fulltextMimetype application/pdf

Personposter BETA

Johansson, SvenHåkansson, LarsClaesson, Ingvar

Søk i DiVA

Av forfatter/redaktør
Johansson, SvenHåkansson, LarsClaesson, Ingvar

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 130 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 118 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf