Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
The effect of a decontamination protocol on contaminated titanium dental implant surfaces with different surface topography in edentulous patients
Trinity College Dublin, IRE.
Dublin Dental University Hospital, IRE.
Trinity College Dublin, IRE.
Blekinge Tekniska Högskola, Fakulteten för teknikvetenskaper, Institutionen för hälsa.
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: Acta Odontologica Scandinavica, ISSN 0001-6357, E-ISSN 1502-3850Artikel i tidskrift (Refereegranskat) Epub ahead of print
Abstract [en]

Objectives: To investigate if it is possible to achieve complete decontamination of dental implant surfaces with different surface characteristics. Materials and methods: Twelve implant pieces with an Osseotite® surface and 12 implant pieces with a Ti-Unite® surface were attached on to the complete lower dentures of six patients and were allowed to accumulate plaque for 30 days. When retrieved, the implant decontamination protocol used, involved both mechanical (PeriBrush™) and chemical (3% H2O2) decontamination. The number of colony forming units per millilitre was determined and the dominant micro-organisms in selected samples was identified by 16s rRNA gene amplicon sequencing. The effect of the titanium brush on the implant surface was examined by SEM. Results: Complete decontamination was achieved in five out of 24 implants (four Osseotite® and one Ti-Unite®). The mean CFU/ml detected after decontamination were 464.48 for Osseotite® and 729.09 for Ti-Unite® implants. On the surface of the implants in which complete decontamination was not achieved, all of the predominant bacteria identified were streptococci except for one which was identified as micrococcus. SEM images revealed that the surface features of the decontaminated implants were not significantly altered. Conclusions: Mechanical decontamination using a titanium brush supplemented with chemical treatment for one minute (3% H2O2) can achieve complete decontamination of implant surfaces in edentulous patients. © 2018, © 2018 Acta Odontologica Scandinavica Society.

Ort, förlag, år, upplaga, sidor
Taylor and Francis Ltd , 2018.
Nyckelord [en]
brush, Decontamination, edentulous, implants, titanium
Nationell ämneskategori
Odontologi
Identifikatorer
URN: urn:nbn:se:bth-17109DOI: 10.1080/00016357.2018.1504986Scopus ID: 2-s2.0-85054094861OAI: oai:DiVA.org:bth-17109DiVA, id: diva2:1255186
Tillgänglig från: 2018-10-11 Skapad: 2018-10-11 Senast uppdaterad: 2018-10-12Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Personposter BETA

Renvert, Stefan

Sök vidare i DiVA

Av författaren/redaktören
Renvert, Stefan
Av organisationen
Institutionen för hälsa
I samma tidskrift
Acta Odontologica Scandinavica
Odontologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 326 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf