Experimental Investigations of Different Microphone Installations for Active Noise Control in Ducts
Ansvarig organisation
2006 (Engelska)Konferensbidrag, Publicerat paper (Refereegranskat) Published
Abstract [en]

A request on ventilation systems today is the feature of a low noise level. A common method to attenuate ventilation noise is to use passive silencers. However, such silencers are not suitable for the lowest frequencies and one solution is to use active noise control (ANC) to increase the noise attenuation in the low frequency range. Normally when using a feedforward ANC system to attenuate duct noise, both the reference microphone and the error microphone are exposed to airflow. As the airflow excites the diaphragm of the microphones, the microphone signals become contaminated by uncorrelated pressure fluctuations that are not part of the sound propagating in the duct. By reducing the flow velocity around the microphones, these uncorrelated pressure fluctuations can be reduced and the noise reduction improved. One way to reduce the flow velocity around the microphones is to place the microphones in outer microphone boxes connected to the duct via a small slit. In this paper a new practical design for the reduction of flow velocity around the microphones is presented; the microphone installation is based on a T-duct, and therefore it makes maintenance and especially construction easier, compared to the microphone box with a slit. Furthermore, comparative results concerning the performance of an ANC system for the two different microphone installations, the T-duct configurations and the microphone boxes with varying slit width, are presented. The results show that the active noise control performance is almost equal when using the suggested microphone installation as compared to when using a microphone box with a slit.

Ort, förlag, år, upplaga, sidor
Vienna, Austria: International Institute of Acoustics and Vibration , 2006.
Nyckelord [en]
active noise control, ventilation systems, duct, microphone windscreen, microphone installation
Nationell ämneskategori
Signalbehandling
Identifikatorer
URN: urn:nbn:se:bth-9410Lokalt ID: oai:bth.se:forskinfoEB150030C9CFF23CC125719900634AC6OAI: oai:DiVA.org:bth-9410DiVA, id: diva2:837248
Konferens
Thirteenth International Congress on Sound and Vibration
Tillgänglig från: 2012-09-18 Skapad: 2006-06-26 Senast uppdaterad: 2015-06-30Bibliografiskt granskad

Open Access i DiVA

fulltext(328 kB)132 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 328 kBChecksumma SHA-512
1b5d9cbd749886a64634b015da097d5ff1931c70bf9fb0c3fbd56f4c6ec465749113b8a3088a3d5abec315000c639c4ffd4d8da79b9ede2664803747763404f7
Typ fulltextMimetyp application/pdf

Personposter BETA

Johansson, SvenHåkansson, LarsClaesson, Ingvar

Sök vidare i DiVA

Av författaren/redaktören
Johansson, SvenHåkansson, LarsClaesson, Ingvar
Signalbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 132 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 104 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf