Sensorless algorithm for sustaining controllability of IPMSM drive in electric vehicle after resolver fault
Gdansk Univ. Technol., POL.
Gdansk Univ. Technol., POL.
Blekinge Tekniska Högskola, Fakulteten för teknikvetenskaper, Institutionen för tillämpad signalbehandling.
2017 (Engelska)Ingår i: Control Engineering Practice, ISSN 0967-0661, E-ISSN 1873-6939, Vol. 58, s. 117-126Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

This paper presents a sensorless algorithm designated for the emergency control of an interior permanent magnet synchronous motor (IPMSM) drive in electric or hybrid vehicle. Special requirements for emergency-activated sensorless algorithms are defined, and shortcomings of state-of-the-art methods in terms of the considered application are discussed. The proposed emergency-activated algorithm is based on analysing the derivatives of motor phase currents measured over the duration of particular inverter states. The method is computationally simple and does not require additional hardware since the derivatives are measured indirectly. A lag between activating the algorithm upon an emergency flying start and re-establishing the torque controllability is defined. The proposed algorithm was implemented in the controller of a laboratory IPMSM vehicle drive and tested under varying operational conditions, including the emergency activation. © 2016 Elsevier Ltd

Ort, förlag, år, upplaga, sidor
Elsevier, 2017. Vol. 58, s. 117-126
Nyckelord [en]
Flying-start, Hybrid electric vehicles, On-board diagnostics, Rotor position estimation, Sensorless control, Chemical activation, Drive-in facilities, Electric machine control, Hybrid vehicles, Permanent magnets, Synchronous motors, Traction motors, Vehicles, Emergency control, Interior permanent magnet synchronous motor drives, On board diagnostics, Operational conditions, Re-establishing, Sensorless algorithms, State-of-the-art methods
Nationell ämneskategori
Signalbehandling
Identifikatorer
URN: urn:nbn:se:bth-13485DOI: 10.1016/j.conengprac.2016.10.004ISI: 000390073900011OAI: oai:DiVA.org:bth-13485DiVA, id: diva2:1049426
Tillgänglig från: 2016-11-24 Skapad: 2016-11-23 Senast uppdaterad: 2017-09-20Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Kulesza, Wlodek

Sök vidare i DiVA

Av författaren/redaktören
Kulesza, Wlodek
Av organisationen
Institutionen för tillämpad signalbehandling
I samma tidskrift
Control Engineering Practice
Signalbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 119 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf