A FEEDFORWARD ACTIVE NOISE CONTROL SYSTEM FOR DUCTS USING A PASSIVE SILENCER TO REDUCE ACOUSTIC FEEDBACK
Ansvarig organisation
2007 (Engelska)Konferensbidrag, Publicerat paper (Refereegranskat) Published
Abstract [en]

Ventilation systems installed in buildings usually generate low-frequency noise because the passive silencers commonly used to attenuate the ventilation noise are not effective in the low-frequency range. A method proven to effectively reduce low-frequency noise in a wide variety of applications is active noise control (ANC). A feedforward ANC system applied to duct noise normally uses a reference microphone, a control unit, a loudspeaker to generate the secondary noise created by the controller, and an error microphone. The secondary noise generated by the loudspeaker will travel both downstream canceling the primary noise, and upstream to the reference microphone, i.e. acoustic feedback. The acoustic feedback may result in performance reduction and stability problems of the control system. Common approaches to solve the feedback problem result in more complex controller structures and/or system configurations than the simple feedforward controller, e.g. introducing a feedback cancellation filter in the controller in parallel with the acoustic feedback path, or using a dual-microphone reference sensing system. This paper presents a simple approach to reduce the acoustic feedback by using a basic feedforward controller in combination with a passive silencer. Simulations show that efficient acoustic feedback cancellation is achieved by using a passive silencer. In the experimental setup another advantage with using a passive silencer is that the frequency response function of the forward path, which is to be estimated, is smoother, i.e. most of the dominant frequency peaks in the frequency response function when not using a passive silencer is reduced. This in turn results in an acoustic path that is less complex to estimate with high accuracy using an adaptive FIR filter steered with the LMS algorithm.

Ort, förlag, år, upplaga, sidor
Cairns, Australia, 2007.
Nyckelord [en]
Signal Processing, Active Noise Control, Ducts, Acoustics, Silencer
Nationell ämneskategori
Signalbehandling
Identifikatorer
URN: urn:nbn:se:bth-9034Lokalt ID: oai:bth.se:forskinfo92C2CC94DBD553D6C12573370071BF9FOAI: oai:DiVA.org:bth-9034DiVA, id: diva2:836810
Konferens
ICSV 14
Tillgänglig från: 2012-09-18 Skapad: 2007-08-14 Senast uppdaterad: 2015-06-30Bibliografiskt granskad

Open Access i DiVA

fulltext(1347 kB)73 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1347 kBChecksumma SHA-512
4a59265d8dc06a7f7da238c6ecfdb8f28eaf40eacb06e88cf055018c78479f046eee4aabfd4e0dd54bd7eb598343b56d4c8e90dc0b23cebd8bc3c5f53f29bf43
Typ fulltextMimetyp application/pdf

Personposter BETA

Johansson, SvenHåkansson, LarsClaesson, Ingvar

Sök vidare i DiVA

Av författaren/redaktören
Johansson, SvenHåkansson, LarsClaesson, Ingvar
Signalbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 73 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 150 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf