Measuring whole body inert gas wash-out
Lund University.
Blekinge Tekniska Högskola, Fakulteten för teknikvetenskaper, Institutionen för matematik och naturvetenskap.ORCID-id: 0000-0002-4629-6324
Lund University.
Lund University.
Vise andre og tillknytning
2023 (engelsk)Inngår i: Diving and Hyperbaric Medicine, ISSN 1833-3516, Vol. 53, nr 4, s. 321-326Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Introduction: Quantifying inert gas wash-out is crucial to understanding the pathophysiology of decompression sickness. In this study, we developed a portable closed-circuit device for measuring inert gas wash-out and validated its precision and accuracy both with and without human subjects. Methods: We developed an exhalate monitor with sensors for volume, temperature, water vapor and oxygen. Inert gas volume was extrapolated from these inputs using the ideal gas law. The device's ability to detect volume differences while connected to a breathing machine was analysed by injecting a given gas volume eight times. One hundred and seventy-two coupled before-and-after measurements were then compared with a paired t-test. Drift in measured inert gas volume during unlabored breathing was evaluated in three subjects at rest using multilevel linear regression. A quasi-experimental cross-over study with the same subjects was conducted to evaluate the device's ability to detect inert gas changes in relation to diving interventions and simulate power. Results: The difference between the injected volume (1,996 ml) and the device's measured volume (1,986 ml) was -10 ml. The 95% confidence interval (CI) for the measured volume was 1,969 to 2,003 ml. Mean drift during a 43 min period of unlaboured breathing was -19 ml, (95% CI, -37 to -1). Our power simulation, based on a cross-over study design, determined a sample size of two subjects to detect a true mean difference of total inert gas wash-out volume of 100 ml. Conclusions: We present a portable device with acceptable precision and accuracy to measure inert gas wash-out differences that may be physiologically relevant in the pathophysiology of decompression sickness. Copyright: This article is the copyright of the authors who grant Diving and Hyperbaric Medicine a non-exclusive licence to publish the article in electronic and other forms.

sted, utgiver, år, opplag, sider
South Pacific Underwater Medicine Society and the European Underwater and Baromedical Society , 2023. Vol. 53, nr 4, s. 321-326
Emneord [en]
Decompression sickness, Diving research, Gas kinetics, Nitrogen, Physiology, Pressure, Cross-Over Studies, Diving, Humans, Oxygen, crossover procedure, human
HSV kategori
Identifikatorer
URN: urn:nbn:se:bth-25827DOI: 10.28920/dhm53.4.321-326ISI: 001163046200005PubMedID: 38091591Scopus ID: 2-s2.0-85179650414OAI: oai:DiVA.org:bth-25827DiVA, id: diva2:1822899
Tilgjengelig fra: 2023-12-28 Laget: 2023-12-28 Sist oppdatert: 2025-09-30bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Silvanius, MårtenFrånberg, Oskar

Søk i DiVA

Av forfatter/redaktør
Silvanius, MårtenFrånberg, Oskar
Av organisasjonen
I samme tidsskrift
Diving and Hyperbaric Medicine

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 109 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf