Implementation of an Algorithm For Estimating Lead-Acid Battery State of Charge
2014 (Engelska)Självständigt arbete på grundnivå (kandidatexamen), 10 poäng / 15 hp
Studentuppsats (Examensarbete)
Abstract [en]
In this paper, an algorithm for estimating lead-acid battery state of charge (SOC) is implemented. The algorithm, named “Improved Coulomb Counting Algorithm”, was developed within a master thesis project (M. M. Samolyk & J. Sobczak, “Development of an algorithm for estimating Lead-acid Battery State of Charge and State of Health”, M.S. thesis, Dept. Signal Processing, Blekinge Institute of Technology, Karlskrona, Sweden, 2013) with cooperation of a Swedish company – Micropower – Research and Development department.
Currently used method at Micropower is Coulomb Counting; implemented algorithm compares coulomb counting method with open circuit voltage method and uses current, terminal voltage and temperature measurements to finally produce improvement for the very same coulomb counting method and get a better estimation of SOC.
The algorithm was implemented on Micropower Access Battery Monitoring Unit (BMU) using C programming language, so that it can be tested in real time application of the regular battery operation. In the end specific gravity measurements were also presented to comparing the methods.
Ort, förlag, år, upplaga, sidor
2014. , s. 22
Nyckelord [en]
Lead-acid battery, State of Charge of the battery, Open circuit voltage, Improved Coulomb counting
Nationell ämneskategori
Teknik och teknologier
Identifikatorer
URN: urn:nbn:se:bth-24116OAI: oai:DiVA.org:bth-24116DiVA, id: diva2:1720726
Externt samarbete
Micropower Sweden AB
Ämne / kurs
ET1464 Kandidatarbete i Elektroteknik
Utbildningsprogram
ETGTC Elektroteknik med inriktning mot telekommunikation
Handledare
Examinatorer
2022-12-202022-12-202025-09-30Bibliografiskt granskad